Back to APN130 Index
CL VFDs Application Note APN130
6. RELIABILITY TEST CONDITIONS
Basically, the CL VFD is subjected to the same reliability test
standards "TT-99-3050A" as the conventional VFDs. For
details on the test conditions, refer to Vacuum Fluorescent Display
Application Note APN101.
7. PRECAUTIONS ON THE HANDLING
- Since the CL VFD contains C-MOS chips, please be cautious
of electrostatic discharge failure. Unpacking of the CL VFD from
the packing tray, mounting or soldering to the PCBs should be
conducted in an environment provided with anti-static measures.
- When the SO terminals are not used, please leave them open.
- Some types of CL VFDs may come equipped with terminals of
same designation. Those terminals with the same designation should
all be connected in parallel.
- Please refer to the power supply sequence in this application
note or individual specification.
- Insert a noise filtering capacitor between "VDD1
"-"GND".
8. WORD IN SPECIFICATION
Spec. No.
The "Spec No."(=revision number) and the date issued
of the specification sheet are sheet is shown in footer of each
sheet. The specification of the standard models are subject to change without prior notice. So,
please check if the revision number of your specification is the
latest version before evaluating it.
Absolute Maximum Ratings
An "Absolute Maximum Ratings" refers to a value
that must not be exceeded in any event. The VFD must not be used
in excess of the value specified under this item. Use of a VFD
in excess of the specified rating may lead to its permanent breakdown.
Therefore, high reliability will be secured if special attention
is paid to the design of a power supply circuit, possible fluctuations
in the supply voltage, surrounding components, operating temperature,
environment, surges or spikes, etc.
Recommended Operating Conditions
"Recommended Operating Conditions" represents the
specification of a recommended operating condition that guarantees
the operation of a VFD. It also serves as a test condition for
which the product is subjected prior to shipment from the factory.
Therefore, it should be noted that if a VFD is used in excess
of the maximum or minimum rating specified here, its operation
and quality will not generally be guaranteed even when such raft
remains within the absolute maximum rating.
In addition, this rated value has been defined assuming the most
standard service conditions by the users. However, some may
want to study the possibility of using the VFDs outside the rated
value, prompted by a desired individual requirement. In such a
case, please feel free to call to consult with us, as we are willing
to discuss the possibility of the proposed specifications.
Test Circuit
It is an example showing how to connect the power supplies. Basically,
the test circuit in the factory inspection is the same as this one.
Electrical (and Optical) Characteristics
All of numbers specified in this section shows the characteristics
when the CL VFDs are tested under the typical (TYP) operating
conditions unless otherwise noted.
Timing Chart
It shows AC characteristics and relationship of interface
operations.
Back to APN130 Index Application Notes Index
APN130
|